sam wrote:
> I've had some doors rehung indoors and need to move the light switches
> as they are now hidden when the door opens.
> I have access to the cabling in the loft but is this something that a
> DIYer can do or do the new regulations require an electrician?
You can do that since it does not fall under the new regulations (i.e.
it is a "minor work"). The exception would be if the switch were in a
bathroom or kitchen.
--
Cheers,
John.
/=================================================================\
| Internode Ltd - http://www.internode.co.uk |
|-----------------------------------------------------------------|
| John Rumm - john(at)internode(dot)co(dot)uk |
\=================================================================/
Date:Thu, 01 Sep 2005 16:04:16 +0100
Author:
|
Re: Swapping light switches
david lang wrote:
> So what jobs are OK and which aren't? I though that if it involved a new
> cable it was banned by the Part P Gestapo. So changing a switch/socket for
> a new one was OK. but as the OP want's to move the switches to the other
> side of the door opening it must involve a new cable?
AIUI the following are OK:
1 Changing accessories
2 Adding a spur to existing circuit power circuit
3 Adding socket to existing ring
4 Replacing a cable section in an existing circuit
5 Adding a lighting point or switch
6 Any amount of life threatening bodgery with "appliances", extension
leads, multiway adaptors
7 Changing a CU fuse, resetting MCB etc.
Things verboten under possible penalty of being shoved up the orifice of
the deputy prime minister include:
8 Adding a complete new circuit (even if it is the better/safer
alternative to copious application of 2 and 3 above)
9 Work in restricted locations[1] (i.e. bathroom and kitchen [2])
10 Work that messes with the CU, Meter, Tails etc (although again open
to discussion if you want to do 4 above on the first/last section of a
circuit).
11 Upgrading earth bonding to modern standards - not because it is in
itself dangerous, but because it would normally required some of 9 above.
[1] Some debate as to if changing an accessory like for like is allowed
[2] Work in a bedroom with on-suite facilities may or may not be covered
depending on the wind direction
So all in all a bit of a dogs breakfast!
--
Cheers,
John.
/=================================================================\